calibration curve comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Updated 2026-05-05. Numbers and descriptions here follow the published literature rather than marketing material.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Common for polar and moderately polar analytes |
| Typical column length | 100-250 mm | Shorter columns can reduce run time |
| Particle size | 3-5 micrometers | Smaller particles improve efficiency but raise pressure |
| Flow rate | 0.5-2.0 mL/min | Depends on column dimensions and pressure limits |
| Detection | UV-Vis absorbance | Widely used for compounds with chromophores |
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Scientific techniques, such as immunostaining, depend on chemical specificity. Immunostaining utilizes the chemical specificity of antibodies in order to detect a protein of interest at the cellular level. Another technique that relies on chemical specificity is Western blotting, which is utilized to detect a certain protein of interest in a tissue. This technique involves gel electrophoresis followed by transferring of the sample onto a membrane which is stained by antibodies. Antibodies are specific to the target protein of interest, and will contain a fluorescent tag signaling the presence of the researcher's protein of interest. Enzyme promiscuity Substrate (chemistry)
Clustal Omega is a multiple sequence alignment (MSA) tool that enables to find an optimal alignment of at least three and maximum of 4000 input DNA and protein sequences. Clustal Omega algorithm employs two profile Hidden Markov models (HMMs) to derive the final alignment of the sequences. The output of the Clustal Omega may be visualized in a guide tree (the phylogenetic relationship of the best-pairing sequences) or ordered by the mutual sequence similarity between the queries. The main advantage of Clustal Omega over other MSA tools (Muscle, ProbCons) is its efficiency, while maintaining a significant accuracy of the results.
Amivantamab, sold under the brand name Rybrevant, is a bispecific monoclonal antibody used to treat non-small cell lung cancer. Amivantamab is a bispecific epidermal growth factor (EGF) receptor-directed and MET receptor-directed antibody. It is the first treatment for adults with non-small cell lung cancer whose tumors have specific types of genetic mutations: epidermal growth factor receptor (EGFR) exon 20 insertion mutations. The most common side effects include rash, infusion-related reactions, skin infections around the fingernails or toenails, muscle and joint pain, shortness of breath, nausea, fatigue, swelling in the lower legs or hands or face, sores in the mouth, cough, constipation, vomiting and changes in certain blood tests. Amivantamab was approved for medical use in the United States in May 2021, and in the European Union in December 2021. The US Food and Drug Administration considers it to be a first-in-class medication.
AnIML Core AnIML Technique Definitions Additionally, AnIML Technique Definition Documents apply constraints to the AnIML Core and are specified by the AnIML Technique Definitions. The AnIML Core consists of a set of rules defining the structure of the XML document, providing a universal container for arbitrary analytical data. AnIML Technique Definitions describe how to use the AnIML Core to record experiments of a particular scientific discipline. There is a big similarity between the mechanisms of AnIML and the AVI format. The AnIML Core defines the data container, whereas the AnIML Technique Definitions act similar to the AVI codec. It defines how the data needs to be structured and labeled. Technique Definitions are XML documents, specified by the Technique Schema. official website AnIML on GitHub
ASQ offers 18 professional certifications relating to various aspects of the quality profession. Professional certification exams are translated into five languages included English, Korean, Mandarin, Portuguese, and Spanish. Exams are given nationally and, to a limited degree, worldwide several times annually. The body of knowledge for each certification is maintained through peer review every few years on a rotating schedule. In 1968, the first ASQ certification was offered. In 2016, ASQ's certification exam delivery method changed from paper to computer-based testing at Prometric nationwide testing facilities. ASQ publishes a range of magazines and journals: Quality Progress Journal for Quality and Participation Journal of Quality Technology Quality Engineering Quality Management Journal Lean & Six Sigma Review Software Quality Professional Technometrics Journal for Quality Perspectives in Knowledge Acquisition Quality Management Forum Primers on Human Development and Leadership ASQ hosts a number of quality events and annual conferences worldwide:
Sources: en.wikipedia.org
Quantitative studies of enzymatic reactions often found that the acceleration of chemical reaction speed cannot be fully explained by existing theories like the approximation, acid/base catalysis and electrophile/nucleophile catalysis. And there is an obvious paradox: in reversible enzymatic reaction if the active site perfectly fits the substrates then the backward reaction will be slowed since products cannot fit perfectly into the active site. So conformational distortion was introduced and argues that both active site and substrate can undergo conformational changes to fit with each other all the time.
The cell membrane can form different types of "supramembrane" structures such as caveolae, postsynaptic densities, podosomes, invadopodia, focal adhesions, and different types of cell junction. These structures are usually responsible for cell adhesion, communication, endocytosis and exocytosis. They are composed of specific proteins, such as integrins and cadherins. They can be visualized by electron microscopy or fluorescence microscopy.
ADAMTS7 was identified as a protease that binds and cleaves COMP in a yeast two-hybrid screen using the epidermal growth factor (EGF) domain of COMP as the bait. However, this initial finding has been contested; a 2025 study demonstrated that purified ADAMTS7 does not exhibit proteolytic cleavage activity toward purified COMP. Furthermore, three independent unbiased N-terminal amine isotopic labeling of substrates (N-TAILS) proteomic studies identified a number of candidate substrates for ADAMTS7 but did not identify COMP as a potential substrate. Consequently, there is as yet no scientific consensus on the physiological function of ADAMTS7. Tissue inhibitor of metalloproteinases 4 (TIMP-4) appears to be the physiological inhibitor of ADAMTS7.
Protein Data Bank (PDB) is a database of three dimensional structures of biological macromolecules, such as proteins and nucleic acids. The data are typically obtained by X-ray crystallography or nuclear magnetic resonance spectroscopy (NMR spectroscopy), and submitted manually by structural biologists worldwide through PDB member organizations – PDBe, RCSB, PDBj and BMRB. The database can be accessed through the webpages of its members, including PDBe (housed at the EMBL-EBI). As a member of the Worldwide Protein Data Bank (wwPDB) consortium, PDBe aids in the joint mission of archiving and maintenance of macromolecular structure data.
AST is similar to alanine transaminase (ALT) in that both enzymes are associated with liver parenchymal cells. The difference is that ALT is found predominantly in the liver, with clinically negligible quantities found in the kidneys, heart, and skeletal muscle, while AST is found in the liver, heart (cardiac muscle), skeletal muscle, kidneys, brain, and red blood cells. As a result, ALT is a more specific indicator of liver inflammation than AST, as AST may be elevated also in diseases affecting other organs, such as myocardial infarction, acute pancreatitis, acute hemolytic anemia, severe burns, acute renal disease, musculoskeletal diseases, and trauma. The elevated AST level in hemorrhagic fever caused by crimean-congo hemorrhagic fever virus is associated with high mortality rate. AST was defined as a biochemical marker for the diagnosis of acute myocardial infarction in 1954. However, the use of AST for such a diagnosis is now redundant and has been superseded by the cardiac troponins. Laboratory tests should always be interpreted using the reference range from the laboratory that performed the test. Example reference ranges are shown below:
Sources: en.wikipedia.org
Outer membrane proteins are membrane proteins with key roles associated with bacterial cell structure and morphology; cell membrane homeostasis; the uptake of nutrients; protection of the cell from toxins including antibiotics; and virulence factors including adhesins, exotoxins, and biofilm formation. There are a number of outer membrane proteins that are specifically virulence-related. Outer membrane proteins consist of two major classes of protein - transmembrane proteins and lipoproteins. The transmembrane proteins form channels or pores in the membrane called porins, and actively pumping efflux channels. The outer membranes of a bacterium can contain a huge number of proteins. In E. Coli for example there are around 500,000 in the membrane. Bacterial outer membrane proteins typically have a unique beta barrel structure that spans the membrane. The beta barrels fold to expose a hydrophobic surface before their insertion into the outer membrane. Beta barrels vary in sequence and size that ranges from 8 to 36 beta strands. A subset of OMPs have a perisplasmic or an extracellular link to their beta barrel structure. An outer membrane protein is translocated across the inner membrane through Sec machinery, and finally inserted to the outer membrane by the barrel assembly machinery complex.
ACC synthase reaches optimal activity in conditions of pH 8.5 and with Km = 20 um relative to its substrate, SAM. ACC Synthase and ethylene biosynthesis are regulated by a whole host of stimuli. Stresses such as wounding, noxious chemicals, auxin, flooding, and indole-3-acetic acid (IAA) promote ethylene synthesis, creating a positive feedback cycle with ACC synthase, up-regulating its activity. However, it is also inhibited by a number of compounds as well. S-Adenosylethionine can bind as a substrate for ACC synthase (with higher affinity than SAM) and therefore inhibit any reaction with SAM. ACC Synthase is also competitively inhibited by aminoethoxyvinylglycine (AVG) and aminooxyacetic acid (AOA), inhibitors to many pyridoxal phosphate-mediated enzymic reactions. They are natural toxins that cause slow binding inhibition by interfering with the coenzyme pyridoxal phosphate. ACC synthase activity is also inhibited by intermediates of the activated methyl cycle and the methionine-recycling pathway: 5′-methylthioadenosine, α-keto-γ-methylthiobutyric acid, and S-adenosylhomocysteine.
APHL works with public health partners to build the foundation for quality testing, comprehensive standards and integrated public health laboratory systems. One of the initiatives, the Laboratory System Improvement Program, provides individual assessments of public health laboratory systems that include engaging stakeholders for system improvement, performance, implementation of strategies and continual evaluation. APHL also collaborates on the National Laboratory System project to build a public-private network of laboratories nationwide. APHL monitors trends in public health laboratory diagnostics, personnel and infrastructure in order to create quality assurance standards. By using these data points to benchmark individual labs against national norms, APHL is able to home in on key issues and help raise the standard of laboratory systems. Member labs have access to research and survey data online, which enables them to leverage new information quickly to identify promising strategies and practices.
Abdominal obesity is typically associated with a statistically higher risk of heart disease, hypertension, insulin resistance, and type 2 diabetes (see below). With an increase in the waist to hip ratio and overall waist circumference the risk of death increases as well. Metabolic syndrome is associated with abdominal obesity, blood lipid disorders, inflammation, insulin resistance, type 2 diabetes, and an increased risk of developing cardiovascular disease. It is now generally believed that intra-abdominal fat is the depot that conveys the biggest health risk. Recent validation has concluded that total and regional body volume estimates correlate positively and significantly with biomarkers of cardiovascular risk and that BVI calculations correlate significantly with all biomarkers of cardiovascular risk. Abdominal obesity is linked with higher cardiovascular events among South Asian ethnic populations.
After translation, the AGP protein backbones are highly decorated with complex carbohydrates, primarily type II AG polysaccharides. The biosynthesis of the mature AGP involves cleavage of the signal peptide at the N-terminus, hydroxylation on the P residues and subsequent glycosylation and in many cases addition of a GPI-anchor. Glycosylation of the AGP backbone is suggested to initiate in the ERTooltip endoplasmic reticulum with the addition of first Gal by O-galactosyltransferase, which is predominantly located in ER fractions. Chain extension then occurs primarily in the GA. For those AGPs that include a GPI anchor, addition occurs while co-translationally migrating into the ER.
Sources: en.wikipedia.org
It measures the amounts and identities of compounds in liquid samples by separation and detection. Depending on the detector and reference standards, results can be qualitative or quantitative. The technique is used in fields such as pharmaceutical analysis, food safety, and environmental monitoring.
Performance checks confirm that the chromatographic system works within preset limits before results are accepted. They examine factors such as peak resolution, tailing, and repeatability. If criteria fail, the run may need correction or repetition.
Retention time alone is not definitive proof because other compounds can elute at similar times. Confirmation usually uses a second method, a different column, or a detector such as mass spectrometry. Authentic standards strengthen identification.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.