quality control comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2026-01-14. Where a claim depends on a specific study, the study is described rather than over-claimed.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Proteomics permits the quantitative analysis and detection of changes to proteins or protein biomarkers. Protein biomarkers detect a variety of biological changes, such as protein-protein interactions, post-translational modifications and immunological responses. Protein biomarkers are widely used in diagnostics due to their direct involvement in cellular functions and pathways. Protein biomarkers can provide direct information about the functional state of cells and tissues, offering insights into disease mechanisms. Techniques such as mass spectrometry, immunohistochemistry, ELISA, and flow cytometry are employed to detect protein biomarkers, which can indicate protein presence and quantification. For example, in about 20% of breast cancers, the cancer cells have an overexpression of the HER2 gene, leading to more aggressive tumor growth. HER2 status can be determined using IHC and FISH. HER2-positive breast cancers are treated with targeted therapies that specifically target the HER2 protein, inhibiting the growth of cancer cells.
Prognosis varies with the type of amyloidosis and the affected organ system. Prognosis for untreated AL cardiac amyloidosis is poor, with a median survival of six months. More specifically, AL amyloidosis can be classified as stage I, II or III based on cardiac biomarkers like Nt-proBNP and cardiac troponin. Survival diminishes with increasing stage, but recent advancements in treatments have improved median survival rates for stages I, II, and III, to 91.2, 60, and 7 months respectively. Outcomes in a person with AA amyloidosis depend on the underlying disease, organ(s) affected, and correlate with the concentration of serum amyloid A protein. People with ATTR, mutant ATTR and wild-type ATTR have a better prognosis when compared to people with AL and may survive for over a decade. Survival time is not associated with gender or age, however, some measures of reduced heart function are associated with a shorter survival time. Senile systemic amyloidosis was determined to be the primary cause of death for 70% of people over 110 who have been autopsied.
Paulovich is a Professor in Clinical Research, an Aven Foundation Endowed Chair, and the Director of Early Detection Initiative at the Fred Hutchinson Cancer Research Center. She was inducted to the American Society for Clinical Inviestigation in 2012. Paulovich is an expert in proteomics. Her targeted proteomics method uses multiple reaction monitoring mass spectrometry to target cancer biomarkers with ongoing clinical trials, and was named Method of the Year in 2012 by Nature Methods. She founded Precision Assays in 2016, whose rights to targeted assays were acquired by CellCarta in 2022. 2014 Life Science Innovation Northwest Woman to Watch in Life Science Award 2015 Human Proteome Organization (HUPO) Distinguished Achievement in Proteomic Sciences Award Identification and use of biomarkers for detection and quantification of the level of radiation exposure in a biological sample (2011) US 20130052668 A1 Compositions and methods for reliably detecting and/or measuring the amount of a modified target protein in a sample (2011) US 20130052669 A1
3-Aminoacetanilide is a chemical compound which is an amino derivative of acetanilide and meta-isomer of aminoacetanilide. There are two other isomers of aminoacetanilide, 2-aminoacetanilide and 4-aminoacetanilide. Aminoacetanilide derivatives are important synthetic intermediates in heterocyclic and aromatic synthesis. These derivatives have found applications in pharmaceutical industry and dyes and pigment industry. A number of methods are available to synthesize 3'-aminoacetanilide. It could be prepared by reduction of m-nitroacetanilide. m-Chloroacetanilde has been converted into m-aminoacetanilide. 3′-Aminoacetanilide has been used in the preparation of azo compounds, pyrrole, imidazole, thiazole and other heterocycles. It is starting material for Trametinib. It is also used to prepare reactive yellow K-RN and dispersed dye.
Sources: en.wikipedia.org
Lactation suppression Hyperprolactinemia Adjunctive therapy of prolactin-producing pituitary gland tumors (prolactinomas); Monotherapy of Parkinson's disease in the early phase; Combination therapy, together with levodopa and a decarboxylase inhibitor such as carbidopa, in progressive-phase Parkinson's disease; In some countries also: ablactation and dysfunctions associated with hyperprolactinemia (amenorrhea, oligomenorrhea, anovulation, nonpuerperal mastitis and galactorrhea); Treatment of uterine fibroids. Adjunctive therapy of acromegaly: Cabergoline has low efficacy in suppressing growth hormone levels and is highly efficient in suppressing hyperprolactinemia, which is present in 20–30% of acromegaly cases. Growth hormone and prolactin are similar structurally and have similar effects in many target tissues; therefore, targeting prolactin may help symptoms when growth hormone secretion cannot be sufficiently controlled by other methods. Cabergoline is frequently used as a first-line agent in the management of prolactinomas due to its higher affinity for D2 receptor sites, less severe side effects, and more convenient dosing schedule than the older bromocriptine, though in pregnancy bromocriptine is often still chosen since there is less data on safety in pregnancy for cabergoline.
The G protein-coupled receptor kinases (GRKs) are protein kinases that phosphorylate only active GPCRs. G-protein-coupled receptor kinases (GRKs) are key modulators of G-protein-coupled receptor (GPCR) signaling. They constitute a family of seven mammalian serine-threonine protein kinases that phosphorylate agonist-bound receptor. GRKs-mediated receptor phosphorylation rapidly initiates profound impairment of receptor signaling and desensitization. Activity of GRKs and subcellular targeting is tightly regulated by interaction with receptor domains, G protein subunits, lipids, anchoring proteins and calcium-sensitive proteins. Phosphorylation of the receptor can have two consequences:
Phage display libraries of 109 randomized sequences are used to screen for Affimer proteins that exhibit high-specificity binding to the target protein with binding affinities in the nM range. The ability to direct in vitro screening techniques allows the identification of specific, high affinity Affimers. In vitro screening and development also mean that the target space for Affimers is not limited by the animal immune system. Affimers are generated using recombinant systems, so their generation is more rapid and reproducible compared to the production of polyclonal antibodies. Multimeric forms Affimers have been generated and shown to yield titres in the range of 200–400 mg/L under small-scale culture using bacterial host systems. Multimeric forms of Affimers with the same target specificity provide avidity effects in target binding. Many different tags and fusion proteins, such as fluorophores, single-stranded DNA, His, and c-Myc tags can be conjugated to Affimers. Specific cysteine residues can be introduced to the protein to allow thiol chemistry to uniformly orient Affimers on a solid support eg ELISA plates. This flexible functionalisation of the Affimer molecule allows functionality across multiple applications and assay formats.
Wheeler was awarded the Lab on a Chip Pioneers in Miniaturization Award (2017), an E.W.R. Steacie Fellowship from the Natural Sciences and Engineering Research Council of Canada (NSERC) (2015), a Connaught Foundation McLean Fellowship (2014), the Joseph Black Award from the Royal Society of Chemistry (2012), the Arthur F. Findeis Award from the American Chemical Society (2012), the Young Innovator Award in Analytical Chemistry (2011), and a Sloan Research Fellowship (2009). In January 2024, Wheeler was honored with the Ricardo Aroca Award, recognizing his contributions to analytical chemistry and advancing lab-on-a-chip techniques, particularly through the use of digital microfluidics (DMF), which enables precise manipulation of liquid droplets on electrode arrays. The Award is bestowed upon a scientist living in Canada who has made a notable contribution to the discipline of analytical chemistry while conducting research within the country.
Creatine is an organic acid naturally occurring in the body (and in red meats) that supplies energy to muscle cells for short bursts of energy (as required in lifting weights) via creatine phosphate replenishment of ATP. Scientific studies have shown that creatine supplementation can increase the consumer's strength, energy during performance, muscle mass, and recovery times after exercise. In addition, recent studies have also shown that creatine improves brain function and reduces mental fatigue. Some studies have suggested that consumption of creatine with protein and carbohydrates can have a greater effect than creatine combined with either protein or carbohydrates alone. While generally considered safe, long-term or excessive consumption of creatine may have an adverse effect on the kidneys, liver, or heart and should be avoided if any pre-existing conditions affecting these organs exist.
Sources: en.wikipedia.org
Akt resides in the cytosol in an inactive conformation, until the cell is stimulated and it translocates to the plasma membrane. The Akt PH domain has a high affinity for second messenger PI(3,4,5)P3, binding to it preferentially over other phosphoinositides. Thus PI3K activity is essential for translocation of Akt to the membrane. Interaction with PI(3,4,5)P3 causes conformational changes and exposure of phosphorylation sites Thr308 in the kinase domain and Ser473 in the C-terminal domain. Akt is partially activated by phosphorylation of T308 by PDK1. Full activation requires phosphorylation of S473, which can be catalysed by multiple proteins, including phosphoinositide-dependent kinase 2 (PDK2), integrin-linked kinase (ILK), mechanistic target of rapamycin complex complex 2 (mTORC2) and DNA-dependent protein kinase (DNA-PK). The regulation of Ser473 phosphorylation is not fully understood but may also be influenced by autophosphorylation after Thr308 phosphorylation. After stimulation, the levels of PIP3 decrease and Akt activity is attenuated by dephosphorylation by serine/threonine phosphatases.
While the initial consolidation of Air Force laboratories reduced overhead and budgetary pressure, another push towards a unified laboratory structure came in the form of the National Defense Authorization Act for Fiscal Year 1996, Section 277. This section instructed the Department of Defense to produce a five-year plan for consolidation and restructuring of all defense laboratories. The currently existing laboratory structure was created in October 1997 through the consolidation of Phillips Laboratory headquartered in Albuquerque, New Mexico, Wright Laboratory in Dayton, Ohio, Rome Laboratory (formerly Rome Air Development Center) in Rome, New York, and Armstrong Laboratory in San Antonio, Texas and the Air Force Office of Scientific Research (AFOSR). The single laboratory concept was developed and championed by Maj Gen Richard Paul, who was Director of Science & Technology for AFMC and Gen Henry Viccellio Jr, and then became the first Commander of AFRL.
Galega officinalis (French lilac) was used in diabetes treatment for centuries. In the 1920s, guanidine compounds were discovered in Galega extracts. Animal studies showed that these compounds lowered blood glucose levels. Some less toxic derivatives, synthalin A and synthalin B, were used for diabetes treatment, but after the discovery of insulin, their use declined. Biguanides were reintroduced into Type 2 diabetes treatment in the late 1950s. Initially phenformin was widely used, but its potential for sometimes fatal lactic acidosis resulted in its withdrawal from most pharmacopeias (in the U.S. in 1978). Metformin has a much better safety profile, and it is the principal biguanide drug used in pharmacotherapy worldwide.
Non-specific active immunotherapy: generating a general immune system response using cytokines and other cell signaling molecules. Specific active immunotherapy: the generation of cell-mediated and antibody immune responses focused on specific antigens expressed by the cancer cells, typically using a vaccine platform. Active immunotherapies fall under the category of activation immunotherapies, which is a subset of immunotherapies that activate the immune system as opposed immunotherapies that suppress the immune system. Non-specific active immunotherapy is administered with the overall goal of generally eliminating malignant pathogens or cells from the host system. This treatment stimulates the immune system in a general sense, rather than specifically targeting a cell type e.g. cancer cells. Non-specific approaches aim to create a robust immune response that would lead to the eventual killing of malignant cells through immunomodulators such as cytokines.
A typical intracellular concentration of ATP is 1–10 μmol per gram of muscle tissue in a variety of eukaryotes. The dephosphorylation of ATP and rephosphorylation of ADP and AMP occur repeatedly in the course of aerobic metabolism. ATP can be produced by a number of distinct cellular processes; the three main pathways in eukaryotes are (1) glycolysis, (2) the citric acid cycle/oxidative phosphorylation, and (3) beta-oxidation. The overall process of oxidizing glucose to carbon dioxide, the combination of pathways 1 and 2, known as cellular respiration, produces about 30 equivalents of ATP from each molecule of glucose. ATP production by a non-photosynthetic aerobic eukaryote occurs mainly in the mitochondria, which comprise nearly 25% of the volume of a typical cell.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
Method validation is the documented process of showing that an HPLC procedure produces reliable results for a defined purpose. It examines parameters such as accuracy, precision, specificity, linearity, and robustness. Regulators and quality systems often require validation before routine use.